Module # |
Function |
Application Program |
Software Function |
PSS # |
FBM201 |
Channel Isolated, 8 Input 0-20 mA |
Analog input |
Conversion time, rate of change limits |
PSS 21H-2Z1 B4 |
FBM202 |
Channel Isolated, 8 Input Thermocouple/mV |
Analog input |
Conversion time, rate of change limits |
PSS 21H-2Z2 B4 |
FBM203 |
Channel Isolated, 8 Input RTD(Platinum, Nickel, Copper) |
Analog input |
Conversion time, rate of change limits |
PSS 21H-2Z3 B4 |
FBM204 |
Channel Isolated, 4 Channel 0-20mA In + 4 Channel 0-20mA Out |
Analog I/O |
Conversion Time, Fail-Safe Configuration(Hold/Fallback on per channel basis) |
PSS 21H-2Z4 B4 |
FBM205 |
Channel Isolated, 4 Channel Redundant 0-20mA In + 4 Channel Redundant 0-20mA Out |
Analog I/O |
Conversion Time, Fail-Safe Configuration(Hold/ Fallback on per channel basis) |
PSS 21H 2Z5 B4 |
FBM207 |
Channel Isolated, 16 DIN Voltage Monitor |
Discrete I/O |
Input filter time |
PSS 21H-2Z7 B4 |
FBM207b |
Channel Isolated, 16 DIN 24VDC Contact Sense |
Discrete I/O, or ladder logic |
Input filter time |
PSS 21H-2Z7 B4 |
FBM207c |
Channel Isolated, 16 DIN 48 VDC Contact Sense |
Discrete I/O, or ladder logic |
Input filter time |
PSS 21H-2Z7 B4 |
FBM213 |
Group Isolated, 8 Input RTD |
Analog input |
Conversion time, rate of change limits |
PSS 21H-2Z13 B4 |
FBM214 |
8 Input Hart Communication, 4-20mA input signal |
Analog input |
Support for the HART commands necessary to interface the field device with the I/A series system database |
PSS 21H-2Z12 B4 |
FBM216 |
Redundant Ready HART Inputs, 8 Channels |
|
|
|
FBM217 |
Group Isolated, 32 Discrete Input |
Discrete I/O, or ladder logic |
Input Filter Time |
PSS 21H-2Z17 B4 |
FBM219 |
Discrete I/O, 32 Channels, 24 DIN voltage monitor+8 DOUT pulse, group isolated |
Discrete I/O, or ladder logic |
Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable. |
PSS 21H-2Z19 B4 |
FBM211 |
Differential Isolated, 16 differential Input 0-20 mA |
Analog input |
Conversion time, rate of change limits |
PSS 21H-2Z11 B4 |
FBM224 |
4 Modbus Communication Channels |
|
Provides a interface between MODBUS salve devices and the Controller Process of I/A series system |
PSS 21H-2Z24 B4 |
FBM231 |
Four Serial Ports, Redundant |
|
Provides a serial interface between dual-ported field I/O devices and I/A series system |
PSS 21H-2Z31 B4 |
FBM233 |
10/100 Mbps Ethernet, Redundant |
|
|
PSS 21H-2Z33 B4 |
FBM237 |
Channel isolated, 8 channel 0-20mA output, redundant |
Analog I/O |
Output Fail-Safe Configuration(Hold/ Fallback on per channel basis£© |
PSS 21H-2Z37 B4 |
FBM241 |
Channel Isolated, 8 channel voltage monitor, 8 channel DOUT pulse, external power |
Discrete I/O, or ladder logic |
Input filter time, Fail-Safe Configuration, Fail-Safe fallback, Sustained and Momentary output. If momentary output configurable is needed, pulse output interval can be also configurable. |
PSS 21H-2Z41 B4 |
FBM242 |
Channel Isolated,16 External Source DO |
Discrete I/O, or ladder logic |
Fail-Safe Configuration |
PSS 21H-2Z42 B4 |
24 Port |
Fiber E'net Switch w/24 MT-RJ Ports & Uplink Ports |
|
Rapid scaling Tee Protocol(RSTR), manages redundant paths, prevent loops, and provides high speed convergence time for a network |
PSS 21H-7C3 B4 |